Laboratory
General
USD | ||
A. | UNDP Contribution (see detailed list in A 5.4) | |
1. Computer (already purchased) | 12.000 | |
2. Gravel/Diatom filters (hatchery) | 39.000 | |
3. Pumps (recirculating systems, hatchery) | 25.500 | |
4. Laboratory equipment | 35.500 | |
Total | 112.000 | |
B. | GOT Contribution | |
Hatchery equipment | ||
1. U.V. Sterilizers | 104.000 | |
2. Pumps (outdoor system) | 63.000 | |
3. Triangle filters | 17.500 | |
4. Air blowers | 9.000 | |
5. Biofilter medium | 7.000 | |
6. Tank vacuum/steam cleaner | 2.000 | |
7. Miscellaneous | 17.500 | |
Hatchery special equipment | ||
Special equipment selected by Turkish engineers | ||
(heating/conditioning, electric and PVC systems) | 50.000 | |
General equipment | ||
1. Pumps (main pumping station): n.4 out of 6 | 170.000 | |
2. Generator: n.1 out of 2 | 60.000 | |
Total | 500.000 |
Hatchery + hatchery office
Laboratory
Office/Didactic
Farm
1. Computer (already purchased)
Software
2. Mechanical filters
Gravel filters: No. 2
Vertical fiter
turbidity reducing capacity: inferior to 5 NTU
flow rate: minimum 25 m3/h
maximum 50 m3/h
pressure: 1.5 to 7 atm
head loss: 1 atm
filtering minerals container: epoxy coated stainless steel
automatic and manual backwash
Diatom filters: No. 2
AISI 304 stainless steel body; epoxy coated and PP
Operating pressure:
minimum: 1 atm
maximum: 2.5 atm
maximum flow: 20 m3/h
Pressure control system equipped with self-cleaning candles
carrying filtering material (diatom powder); made from stainless
steel springs covered with PP stocking
Dissolved oxygen probes YSI 5739: No. 4
Probe cables YSI 5740–10 No. 4
Probe service kits (membrane + KCE) YSI 5775: No. 2
Spectrophotometer: No. 1
Ciba-Corning (mod 259) or Pye Unicam
Wavelenght range 330 – 900 nm; bandpass ±7nm; glass cell 10 mm
path length and 40 mm path length autocell; wavelength accuracy
±2 nm
Filtration equipment: No. 1
Millipore
Vacuum pump with manostat; filter holder
Clinical centrifuge: No. 1
Claudon (mod. T51 Micro)
Carrier 8 × 15 ml; max. speed 4200 r.p.m.
Furnace: No. 1
Mod. EML 11/6
Volume: 6.4 1; 220 – 240 V; max.temp. 1100 °C
pH meter: No. 2
WTW (mod. pH 196)
Portable digital meter with automatic temperature compensation;
direct measure of temperature and millivolts; 3 m probe cable.
pH stick meter: No. 3
Astell (mod. PMA 576)
Automatic temperature compensation; splashproof membrane
switching; range pH: 0 – 14; resolution: 0.01; accuracy: ± 0.02
Temperature stick meter: No. 3
Astell (mod. TMA 582)
Range: -30 +150 °C; resolution: 0.1 °C; accuracy ±0.5 °C.
Imhoff sedimentation system: No. 1
Azlon (mod. SWX 006)
Rectangular stand, 3 cones.
Incubator: No. 1
Astell Hearson (mod. JBH 000)
Volume 180 l; temperature range, ambient 20 °C: -10 +50 °C;
temperature fluctuation: ± 0.1 °C.
Peristaltic pumps for HC10 injection: No. 2
Complete of suction and injection kit
Qmax = 27 l/h
Pressure : 10 bar
Accuracy : ± 4%
Power: 380V; 50Hz; 60W
PVC-head PTFE-membrane
Spare parts
Diatom powder for filters: kg 100
sand filter filling material: No. 6
3. Pumps
Centrifugal single stage vertical axis electropumps with cast
iron bearing housing. All parts in contact with sea water must
be of plastic (PVC; PP; PVDF…etc.), 3-phase motors 380 V/50 Hz
IP 55 protection with following capacity:
minimum 10 m3/h; head 9 m : No. 4
minimum 45 m3/h; head 12 m : No. 6
All-round transportable pumps: No. 6
centrifugal submersible electropumps made entirely by polymers.
Automatic level control (mercury switch); 3-phase motor; 380V/50Hz
flow rate: 10 m3/h; head: 2–3 meters
4. Laboratory equipment
Digital YSI oxygen meter: No. 2
Sensing element: Clark type membrane covered polarographic
electrode temperature compensated from ± 3% of D.O. readings
from - 5 °C to 40 °C
Range of measurement: oxygen 0–5; 0–10; 0–20 ppm; accuracy
± 0.1 ppm;
temperature - 5 °C to 45 °C; accuracy ± 0.5 °C
B.O.D. glass oxygen bottles: No. 50
Babcock (mod. BJM 372)
Capacity: 250 ml.
Homogeniser: No. 1
Azlon (mod. HWN 848)
Potter sterilisable homogeniser; virgin p.t.f.e. piston and glass
cylinder 15 ml capacity.
Electronic balance: No. 1
Mettler (mod. PM 3000)
Weighing range: 3100 g; readability: 0.1 g; fully subtractive
tare.
Bacteriological incubator: No. 1
Temp.: +25 +80 °C; accurancy: ±0.2 °C; vol.: ±200 l; power:
220V, 50Hz; transparent door.
Oven: No. 1
Temp.: +40 +240 °C; accurancy: 1 – 2 °C; vol.: ±200 l; power:
220V, 50Hz.
Portable salinometer: No. 1
Scale 0–45 ppt; division 1 ppt also with temperature compensation
0 to +30 °C
Electronic thermometer: No. 4
Scale -20 °C to +125 °C
Precision 0.1 °C
Display ½" LCD
Platic probe with stainless steel terminal part and NPN
microtransistor, complete with batteries.
Optical refractometer (Salinometer): No. 2
Aluminium: waterproof
Scale: 0–45 ppt
Division: 1 ppt
Automatic temperature compensation 0 to 30° C
Technical balance: No. 1
Epoxy coated, electronic mechanical balance.
Stainless steel or plastic plate
Weighing range: 0.1–2200 g;
Division: 0.01 g
Measuring time: 2 seconds
Automatic
Power supply 220 V/50 Hz
Refrigerated thermostat incubator: No. 1
Electronic thermostat and digital thermometer forced air
ventilation
internal socket
Temp.: -20° C +50° C, div 1/1
Power: 220 V/50 Hz
Inner neon lamps with timer electric heater
Approx. ext. volume 0.6 m3
Stereo microscope: No. 1
Zoom binocular head
inclination: 45°
Eyepieces: interpupillary
adjustment 10 ×; 20 ×
Zoom objectives: from 0.7 to 2.4
Illumination: transmitted and incident with built-in
transformer for 6 V; 1.2 A
Optical microscope: No. 1
with high power definition
Binocular head: 45° inclination, 360° rotation, locable at any
angle.
Eyepieces 5×; 10×; 14×
Objectives: × 4; × 10; × 40; × 100 (oil)
Illumination adjustable
Intensity control: Tungsten-halogen low voltage lamp (10 W/6 V)
and built-in transformer
Focusing: macro and micrometric
Stages: graduated low position coaxialmechanical stage with
Vernier scales reading to 0.1 mm
Condenser: ABBE, two lens type, NA Iris diaphragm and daylight
blue filter.
1. PUMPS (submerged)
Please report all inclusive amounts/give details-specifications-explanations in annex
Equipment specifications | Number | Basic offer | Possible alternative | ||||
Unit price | Total price | Unit price | Total price | ||||
in US$ | in … | in US$ | in … | ||||
A) SUPPLY TO BEYMELEK (project site) | |||||||
1. Pumps + cables (60 M) | |||||||
2. Propellers | |||||||
3. Shafts | |||||||
4. Epoxy | |||||||
5. Anodes | |||||||
6. Pipes | |||||||
7. Grates | |||||||
8. Elec. panels | |||||||
sub-tot. A | |||||||
B) ASSEMBLY, including | |||||||
1. Specialist intervention (from manifacturer) | |||||||
2. Tests and regulations | |||||||
3. Putting into service | |||||||
sub-tot. B | |||||||
C) MAINTENANCE: | |||||||
Annual cost of interventions | |||||||
sub-tot. C | |||||||
Total (A + B + C) |
Furthermore, offer must include also following:
DETAILED GARANTIES
Please specify years of guarantee, precise terms of replacement of defective, broken or worn-out parts within time of guarantee, etc.
TIME OF INTERVENTION
Please specify guaranteed maximum time of specialist intervention for restarting of pump(s) after breakdown.
SPARE PARTS
Please give detailed list of spare parts available in own store and relative price list.
2. ELECTRIC GENERATORS
Equipment specification | Number | Unit price | Total price | ||
in US$ | in … | in US$ | in … | ||
A) SUPPLY TO BEYMELEK (project site) | |||||
1. 260/285 KVA generators including | 2 | ||||
- starting equipment | |||||
- control board | |||||
2. Boards - synchronization | 1 | ||||
- normal/emergency (automatique) | 1 | ||||
3. Mechanical equipment | |||||
- daily reservoir 1.200 1 | 2 | ||||
- main reservoir 12.000 1 | 2 | ||||
sub-tot. A | |||||
B) ASSEMBLY, including | |||||
1. Specialist intervention (from manufacturer) | |||||
2. Tests and regulations | |||||
3. Putting into service | |||||
sub-tot. B | |||||
C) MAINTENANCE : | |||||
Annual cost of interventions | |||||
sub-tot. C | |||||
Total (A + B + C) |
Furthermore, offer must include also following:
DETAILED GARANTIES
Please specify years of guarantee, precise terms of replacement of defective, broken or worn-out parts within time of guarantee, etc.
TIME OF INTERVENTION
Please specify guaranteed maximum time of specialist intervention for restarting of generator(s) after breakdown.
SPARE PARTS
Please give detailed list of spare parts available in own store and relative price list.